Maxtech Industries

Cement Mill

When to use membrane filter bags:

  • Frequent choking of conventional filter bags
  • High baghouse pressure drop 
  • Handle larger air flow and production rate
  • Reduce maintenance and emissions 

Generally ball mills are employed for clinker grinding, additives like limestone, pond ash, fly ash, gypsum, and slag are added depending upon the grade of the cement.

Operating Data

Bag filter is used for venting of Mills.

  • Dust Handled: Cement Dust 
  • Design Temperature: 127 deg C for Polyester and 135 deg C for Acrylic 
  • Surge Temperature: 140 deg C for Acrylic and 150 deg C for Polyester
  • Dust Load: 30-600 g/Nm3

 

Filter MediaPolyester FeltAcrylic Homopolymer Felt
 

When To UseLow moisture and temperature combinationHigh moisture and temperature combination